Dimensions

  • Length(mm):
    1800
  • Width(mm):
    2200
  • Height(mm):
    1980
  • Weight (kg):
    2200
  • Lifting/ Transportation:
    Frame with forklift channels and lifting slings. Slings and shackles in acc. to DNV 2.7-1.

Construction year

  • Built:
    1991

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde II T3 Zone 1

Flow / Pressure / Volume

  • Tank Volume (ltr):
    1200
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    420
  • Hz v P-max measure:
    60
  • P-max (bar):
    210
  • Min. viscosity (cst):
    13
  • Max. Viscosity (cst):
    68
  • Start Viscosity (cst):
    220

Connections

  • Inlet connection:
    2 ea 1" BSP
  • Outlet connection:
    2 ea 1" BSP

Pump(s)

  • Pump1 (type):
    Vickers PVH. 131C-RF-135-10-C21VT10-14
  • Pump2 (type):
    Vickers PVH. 131C-RF-135-10-C21VT10-14

Motor / Engine(s)

  • Motor1 (type):
    Teve Varnost 3KTC 225 S-4
  • Motor1 (Cert. No.):
    227
  • Motor2 (type):
    Teve Varnost 3KTC 225 S-4
  • Motor2 (Cert. No.):
    257

Power supply

  • Fuse (qty):
    2
  • Fuse (A):
    125
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    37
  • (A):
    67
  • El.Power2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    37
  • (A):
    38,7
  • El.Power3:
    400-480 VD
  • (Hz):
    60
  • (kW):
    42,5
  • (A):
    66,5
  • El.Power4:
    660-690 VY
  • (Hz):
    50
  • (kW):
    37
  • (A):
    38,2
  • Starter:
    Stahl Eexde IIC T5 Ser. no. 44765, 400-690 V 50-60 Hz Max. load: 146 A

Filter

  • Filter outlet (qty):
    2
  • Filterhouse (type):
    Finnfilter FF 7008 F003 BK 35 GL24
  • Filterelement (type):
    Finnfilter D143G03A
  • Filter inlet (qty):
    2
  • Filterhouse (type):
    Parker 34P-2
  • Filterelement (type):
    Parker D731G03A

Additional information

  • Equipment / Functions:

    Q-MAX IS TOTAL FLOW FOR BOTH PUMPS (PUMP 1: 210 ltr/min - PUMP 2: 210 ltr/min).

    Flow indicator, level switch, heat exchanger and outlet for samples.

    30 m remote controlled emergency stop, which sops both motors at the same time

    (NB! Motor protection has to bee changed if used over 480 V)