Dimensions

  • Length(mm):
    3800
  • Width(mm):
    2800
  • Height(mm):
    2800
  • Weight (kg):
    9300
  • Lifting/ Transportation:
    Frame with forklift channels

Construction year

  • Built:
    1995
  • Upgraded/rebuilt:
    2009

Area of use / certification

  • Onshore/offshore:

    Onshore

Flow / Pressure / Volume

  • Tank Volume (ltr):
    3000
  • Hz v Q-max measure:
    50
  • Q-max (l/min):
    1540
  • Hz v P-max measure:
    50
  • P-max (bar):
    350
  • Flowrate1:
    500 ltr/min @ 350 bar
  • Flowrate2:
    1080 ltr/min @ 200 bar
  • Flowrate3:
    1540 ltr/min @ 100 bar
  • Min. viscosity (cst):
    16
  • Max. Viscosity (cst):
    100
  • Start Viscosity (cst):
    800

Connections

  • Inlet connection:
    2 ea 2" BSP and 1 ea 1" BSP
  • Outlet connection:
    2 ea 2" BSP male

Pump(s)

  • Pump1 (type):
    4 ea Parker PV270 ccm

Motor / Engine(s)

  • Motor1 (type):
    2 ea Mez Drasov 4.AEB 315 M04

Power supply

  • Fuse (qty):
    2
  • Fuse (A):
    450
  • El.Power1:
    400 V
  • (Hz):
    50
  • (kW):
    200
  • (A):
    360
  • El.Power2:
    440 V
  • (Hz):
    60
  • (kW):
    240
  • (A):
    360
  • Starter:
    2 ea. General Elektro DOL, Max. load: 108 A

Filter

  • Filter outlet (qty):
    4
  • Filterhouse (type):
    38P210QBM3MG241
  • Filterelement (type):
    G04284, D781G03A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Finnfilter FK 1113 Q005-BS16-SX64
  • Filterelement (type):
    R742G03
  • Filter Internalcirculation (qty):
    1
  • Filter (type):
    FF1147Q10BS35GT24
  • Filterelement (type):
    D142G03A

Additional information

  • Equipment / Functions:

    Q-MAX IS TOTAL FLOW FOR BOTH PUMPS (PUMP 1: 770 ltr/min - PUMP 2: 770 ltr/min).

    Cable size - Main power 1:

    1 x 150 mm² single conductor x 3

    1 x 95 mm² single conductor x 1 (PE Earth)

    Cable size - Main power 2:

    1 x 150 mm² single conductor x 3

    1 x 95 mm² single conductor x 1 (PE Earth)

    Flowindicator, pressure regulator, thermometer, heating exchanger (aircooled), levelglass.

    The unit need external control current 230 V 1phase.

    The unit is delivered without feeder mains as standard.